Specifies requirements and test methods for verifying electromagnetic compatibility of pacemakers
Cardiac pacemakers - Specification for implantable cardiac pacemakers - Electromagnetic compatibility
External cardiac pacemaker
이 규격은 심근에 접촉하는 전극을 사용하여 심장에 전기 자극을 줌으로써 부정맥을 보정하고
External cardiac pacemaker
本文件规定了用于评价可与经静脉电极导线系统一起提供一种或多种心动过缓、心动过速和心脏再同步等治疗的有源植入式心血管器械的电磁兼容(EMC)试验方法。本文件规定了此类器械与可运行于下列两个EM频谱范围内的EM发射器发生相互作用时的性能界限:0 Hz ≤ f < 385 MHz;385 MHz ≤ f
Lithium-iodine batteries for cardiac pacemakers
Implants for surgery — Cardiac pacemakers — Part 1: Implantable ventricular pacemakers
Implants for surgery-Cardiac pacemakers-Part 1:Implantable pacemakers
Active implantable medical devices - Electromagnetic compatibility - EMC test protocols for implantable cardiac pacemakers, implantable cardioverter defibrillators and cardiac resynchronization devices
Implants for surgerjr. Implantable cardlac pacemakers
Cardiac pacemakers; part 1: implantable pacemakers
本标准规定了植入式心脏起搏器电极导管的技术要求、试验方法以及标志、包装、运输和贮存。 本标准适用于植入式心脏起搏器电极导管。电极导管连接器的特性由YY/T 0491-2004规定。 本标准对不同的电极导管与脉冲发生器所组成的起搏器系统的功能相容性或可靠性方面没有作论述
Implantable pacing lead
This standard sets forth a comprehensive test methodology for the evaluation of the electromagnetic (EM) compatibility of active implantable
Active implantable medical devices - Electromagnetic compatibility - EMC test protocols for implantable cardiac pacemakers and implantable cardioverter defibrillators
本标准规定了用于将植入式心脏起搏器电极导管连接至植入式心脏起搏器脉冲发生器的连接器组件,并规定了基本尺寸、性能要求以及相应的试验方法。其他的插头性能,紧固方法和材料在本标准中没有作出规定,也没有涉及将不同电极导管与脉冲发生器组成起搏器系统的功能上的兼容性或可靠性问题的各个方面。 若植入式
Cardiac pacemakers-Low-profile connectors(IS-1) for implantable pacemakers
Safety of implantable cardiac pacemakers; protection against electrical-magnetic interferences
Specifies requirements and test methods for verifying electromagnetic compatibility of pacemakers
Cardiac pacemakers - Specification for implantable cardiac pacemakers - Electromagnetic compatibility
External cardiac pacemaker
이 규격은 심근에 접촉하는 전극을 사용하여 심장에 전기 자극을 줌으로써 부정맥을 보정하고
External cardiac pacemaker
本文件规定了用于评价可与经静脉电极导线系统一起提供一种或多种心动过缓、心动过速和心脏再同步等治疗的有源植入式心血管器械的电磁兼容(EMC)试验方法。本文件规定了此类器械与可运行于下列两个EM频谱范围内的EM发射器发生相互作用时的性能界限:0 Hz ≤ f < 385 MHz;385 MHz ≤ f
Lithium-iodine batteries for cardiac pacemakers
Implants for surgery — Cardiac pacemakers — Part 1: Implantable ventricular pacemakers
Implants for surgery-Cardiac pacemakers-Part 1:Implantable pacemakers
Active implantable medical devices - Electromagnetic compatibility - EMC test protocols for implantable cardiac pacemakers, implantable cardioverter defibrillators and cardiac resynchronization devices
Implants for surgerjr. Implantable cardlac pacemakers
Cardiac pacemakers; part 1: implantable pacemakers
本标准规定了植入式心脏起搏器电极导管的技术要求、试验方法以及标志、包装、运输和贮存。 本标准适用于植入式心脏起搏器电极导管。电极导管连接器的特性由YY/T 0491-2004规定。 本标准对不同的电极导管与脉冲发生器所组成的起搏器系统的功能相容性或可靠性方面没有作论述
Implantable pacing lead
This standard sets forth a comprehensive test methodology for the evaluation of the electromagnetic (EM) compatibility of active implantable
Active implantable medical devices - Electromagnetic compatibility - EMC test protocols for implantable cardiac pacemakers and implantable cardioverter defibrillators
本标准规定了用于将植入式心脏起搏器电极导管连接至植入式心脏起搏器脉冲发生器的连接器组件,并规定了基本尺寸、性能要求以及相应的试验方法。其他的插头性能,紧固方法和材料在本标准中没有作出规定,也没有涉及将不同电极导管与脉冲发生器组成起搏器系统的功能上的兼容性或可靠性问题的各个方面。 若植入式
Cardiac pacemakers-Low-profile connectors(IS-1) for implantable pacemakers
Safety of implantable cardiac pacemakers; protection against electrical-magnetic interferences