Magnetic resonance equipment for medical diagnosis
Magnetic resonance equipment for medical diagnosis
本规程适用于使用中和修理后的连续波高频小调场式电子顺磁共振(EPR)波谱仪(X波段)的检定
本标准规定了用连续波低分辨率核磁共振测定法快速测定油籽含油量的定义、仪器、样品制备、测定步骤及结果计算。 本标准适用于在20℃不含完全呈液体油的油籽。如:油菜籽、芝麻、大豆、葵花籽、棉籽、花生等
Determination of oil content in oilseeds by nuclear magnetic resonance method
Surface chemical analysis — Determination of the minimum detectability of surface plasmon resonance device
本标准规定了磁共振引导微创手术室的组成及设备配置要求。本标准适用于磁共振引导的微创手术室的构建
Configuration for MRI-guided minimally invasive therapy suite
Verification Regulation of Grating Linear Displacement Measuring Device
目前国内尚未制定水质17O-NMR半高峰宽测定标准,本文件的提出,旨在统一规范目前市场上17O-NMR半高峰宽的测定技术,以“17O-NMR半高峰宽(17O-NMR FWHM)”技术指标代替“小分子团”的概念
Determination of 17O-NMR FWHM in Water NMR Method
1.1 This standard test method covers the measurement of the magnetically induced displacement force produced by the spatial gradients of a magnetic
Standard Test Method for Measurement of Magnetically Induced Displacement Force on Passive Implants in the Magnetic Resonance Environment
1.1 This test method covers the measurement of the magnetically induced displacement force produced by static magnetic field gradients on medical
Standard Test Method for Measurement of Magnetically Induced Displacement Force on Medical Devices in the Magnetic Resonance Environment
Fixed railway installations. Signalling. Wire transmissions. Readjusting devices. Counterbalance lenses.
1.1 This standard test method covers the measurement of the magnetically induced displacement force produced by the spatial gradients of a magnetic
Standard Test Method for Measurement of Magnetically Induced Displacement Force on Passive Implants in the Magnetic Resonance Environment
1.1 This test method covers the measurement of the magnetically induced displacement force produced by static magnetic field gradients on medical
Standard Test Method for Measurement of Magnetically Induced Displacement Force on Medical Devices in the Magnetic Resonance Environment
1.1 This test method covers the measurement of the magnetically induced displacement force produced by static magnetic field gradients on medical
Standard Test Method for Measurement of Magnetically Induced Displacement Force on Medical Devices in the Magnetic Resonance Environment
This test method is one of those required to determine if the presence of a medical device may cause injury to individuals during an MR
Standard Test Method for Measurement of Magnetically Induced Displacement Force on Medical Devices in the Magnetic Resonance Environment
5.1x00a0;This test method is one of those required to determine
Standard Test Method for Measurement of Magnetically Induced Displacement Force on Medical Devices in the Magnetic Resonance Environment
Class A magnetic compasses, azimuth readingdevices and binnacles-Tests and certification
Standard practice for marking medical devices and other items for safety in the magnetic resonance environment
Device for reporting stop name in bus and trolley bus. Tape playback
目前国内尚未制定水质17O-NMR半高峰宽测定标准,本文件的提出,旨在统一规范目前市场上17O-NMR半高峰宽的测定技术,以“17O-NMR半高峰宽(17O-NMR FWHM)”技术指标代替“小分子团”的概念
Determination of 17O-NMR FWHM in Water NMR Method
Medical devices and other items have caused serious injuries and death for patients and other individuals in the MR environment.
Standard Practice for Marking Medical Devices and Other Items for Safety in the Magnetic Resonance Environment
Medical devices and other items have caused serious injuries and death for patients and other individuals in the MR environment.
Standard Practice for Marking Medical Devices and Other Items for Safety in the Magnetic Resonance Environment
Mechanical vibration. Vibration of rotating machinery equipped with active magnetic bearings. Vocabulary
5.1x00a0;This test method is one of those required to determine
Standard Test Method for Measurement of Magnetically Induced Displacement Force on Medical Devices in the Magnetic Resonance Environment