WS 816-2023 医用质子重离子质量控制标准

DB22/T 1863-2013 质量控制与规范

KS C IEC 61859:2007 机房计导则

이 규격은 방사선 장비를 사용하는 동안 환자, 구동자, 기타 사람들의 안전을 보증하는 설비

Guidelines for radiotherapy treatment rooms design

IEC TR3 61859:1997 机房计导则

This technical report applies only to those aspects of the installation ensuring the safety of the patient, the operator and other persons during

Guidelines for radiotherapy treatment rooms design

NF C74-235*NF EN 62274:2005 医电气 记录和定系统的安全

Medical electrical equipment - Safety of radiotherapy record and verify systems

DIN 6875-2:2008 专用.第2部分:经由皮肤的立体法.稳定性

Special radiotherapy equipment - Part 2: Percutaneous stereotactic radiotherapy - Constancy testing

IEC 61217-2011 - 坐标 运动和秤

Radiotherapy equipment - Coordinates, movements and scales

GOST R IEC/TR 62266-2009 医电气. DICOM实施指南

Medical electrical equipment. Guidelines for implementation of DICOM in radiotherapy

DIN 6875-4:2011 专业.第4部分:可调强度.稳定性试验

Special radiotherapy equipments - Part 4: Intensity-modulated radiation therapy - Constancy testing

GB/T 18987-2003 坐标系、运动与刻度

本标准适用于远距离放射治疗过程中有关的设备与数据,包括与放射治疗计划系统、放射治疗模拟机、等中心y射束治疗设备、等中心医用电子加速器以及非等中心设备有关的患者影像数据。 本标准规定了一套用于远距离放射治疗整个过程都使用的坐标系,规定了用于这一过程中的刻度标记(提供之处),以及设备的运动,如使用

Radiotherapy equipment--Coordinates,movements and scales

GB/T 18987-2015 坐标、运动与刻度

本标准适用于远距离放射治疗过程中有关的设备与数据,包括与放射治疗计划系统、放射治疗模拟机、等中心7射束治疗设备、等中心医用电子加速器以及非等中心设备有关的患者影像数据。 本标准的目的是规定用于远距离放射治疗整个过程都使用的一套相容的坐标系、用于这一过程中的刻度标记(提供之处)和设备的运动,以及使用

Radiotherapy equipment.Coordinates, movements and scales

KS C IEC 61217:2017 坐标、运动和刻度

Radiotherapy equipment-Coordinates, movements and scales

KS C IEC 61217:2021 .坐标、运动和刻度

Radiotherapy equipment — Coordinates, movements and scales

GBZ 121-2020 防护要求

本标准规定了放射治疗的放射防护要求。本标准适用于利用医用电子加速器、钴-60治疗机、中子放射源及γ放射源后装治疗机、X射线及γ射线立体定向放射治疗系统、螺旋断层放射治疗系统、术中放射治疗的移动式电子加速器、医用X射线治疗机、低能X射线放射治疗设备和质子重离子加速器等设备开展放射治疗的防护要求。本标准

AS/NZS 3824-1998 计指南

Applies to those aspects of a radiotherapy installation which ensure the safety of the patient, the equipment operator and other persons present

Guidelines for radiotherapy treatment rooms design

IEC 61217:2011 . 坐标系、运动与刻度

Radiotherapy equipment - Coordinates, movements and scales

IEC 61217:1996 坐标系、运动和刻度

Object is to define a consistent set of coordinate systems for use throughout the process of teleradiotherapy, to define the marking of scales

Radiotherapy equipment - Coordinates, movements and scales

GOST R IEC 61217-2013 . 坐标系, 运动和刻度

Radiotherapy equipment. Coordinates, movements and scales

NF C74-212/A1:2001 .坐标值、移动量和定标

Radiotherapy equipment - Coordinates, movements and scales.

NF C74-212*NF EN 61217:2012 坐标值、移动量和定标

Radiotherapy equipment - Coordinates, movements and scales

NF C15-162:1977 X线产生和使用.的特殊要求

Installations for the generation and application of X-rays. Particular requirements for X-ray therapy installations.

NF C74-212:1997 的坐标值、移动量和定标

Radiotherapy equipment coordinates, movements and scales.

IEC 61217/AMD2:2007 .坐标、运动和尺度.修正件2

This standard is about Radiotherapy equipment - Coordinates, movements and scales; Amendment 2

Radiotherapy equipment - Coordinates, movements and scales; Amendment 2

YY/T 0888-2013 中X线图像引导装置的成像剂量

本标准规定了放射治疗设备中X射线图像引导装置的成像剂量试验方法和对随机文件的要求。本标准适用于放射治疗设备中X射线图像引导装置

Imaging dose of X-ray image-guided devices used in radiotherapy equipment

WS 816-2023 医用质子重离子质量控制检测标准

YY 1650-2019 X线图像引导 性能和试验方法

ANSI N449.1-1978 钴60和铯137远距的周期检验程序

This guideline provides suggested proceduresfor the inspection of cobalt-60 and cesium-137teletherapy equipment which may identify andquantify

Procedures for periodic inspection of cobalt-60 and cesium-137 teletherapy equipment

IEC TR3 61852:1998 医用电气 医用数字成像和通信(DICOM)

This report specifies the following information objects: 1) A DICOM Image Information Object for Radiotherapy. It specifies the semantic content of RT

Medical electrical equipment - Digital imaging and communications in medicine (DICOM) - Radiotherapy objects

KS C IEC 61852:2007 医用电气.医用数字成像和通信(DICOM).

이 보고서는 다음 정보 객체를 기술한다.1) 방사선 치료 DICOM 영상 정보 객체(D

Medical electrical equipment-Digital imaging and communications in medicine(DICOM)-Radiotherapy objects

EN 61217:1996 .坐标系/运动与刻度;包含修改件A2:2008年2月

Radiotherapy Equipment - Co-Ordinates, Movements and Scales (Incorporates Amendment A2: 2008; Remains Current)