本规范适用于新制造、使用中及修理后的普通心脏除颤器(以下简称除颤器)和心脏除颤监护仪(以下简称除颤监护仪)除颤部分(含除颤过程中除颤部分对心电监护部分的影响)的校准;不适用于自动外部除颤器、体内植入式除颤器的校准,除颤监护仪心电的计量特性及其校准可参照JJG 760-2003 心电监护仪检定
Calibration Specification for Cardiac Defibrillators & Cardiac Defibrillator-monitors
Contains guidelines regarding maintenance to be performed by clinical engineering personnel. Does not apply to automatic implantable defibrillators
Cardiac defibrillators; cardiac defibrillators-monitors; part 2: maintenance
Contains guidelines regarding the safe and effective operation and maintenance to be performed by medical and nursing personnel. Does not apply
Cardiac defibrillators; cardiac defibrillators-monitors; part 1: operation
本标准适用于直接测量或直接探测由发射光子辐射的核素造成表面污染的便携式和移动式污染测量仪和监测仪,它至少包括:--探测装置(计数管、闪烁探测器或半导体探测器等),它们可以采用刚性连接或电缆连接或者组成一单独的装置;--测量装置。本标准适用于:--表面污染光子测量仪;--表面污染光子监测仪。本标准
Radiation protection instrumentation.Portable photon contamination meters and monitors
补充: 本标准规定了在2.1.101条和2.1.102条中定义的心脏除颤器和心脏除颤器监护仪的安全要求,下文称之为设备,它具有电容性的能量储存装置。 本标准不适用于不是除颤器监护仪的组成部分的心脏监护仪。 在心电(ECG)监视信号不能从除颤器电极得到的组合设备中,本标准仅
Medical electrical equipment. Part 2: Particular requirements for the safety of cardiac defibrillators and cardiac defibrillator-monitors
This International Standard is applicable to portable and transportable contamination meters and monitors designed for the direct measurement
Radiation protection instrumentation. Portable photon contamination meters and monitors
This International Standard is applicable to portable and transportable contamination meters and monitors designed for the direct measurement
Radiation protection instrumentation - Portable photon contamination meters and monitors
本文件规定了便携式除螨吸尘器的术语和定义、产品分类、要求、试验方法、检验规则、标识、包 装、运输和贮存等要求
Portable mites removing vacuum cleaner
Portable X or gamma radiation exposure rate meters and monitors for use in radiological protection
This International Standard specifies requirements for classification of wire electrodes in the as-welded condition and in the post weld heat-treated
Cardiac Defibrillators - Cardiac Defibrillators-Monitors - Part 2: Maintenance First Edition; CEI/IEC 1288-2: 1993
Low energy X or gamma radiation portable exposure rate meters and monitors for use in radiological protection
1 范围 2 规范性引用文件 3 术语和定义 4 一般要求 4.1 正常工作条件 4.2 设备用图形符号 4.3 技术要求 5 试验方法 5.1 工作条件
Portable LED Projector
本规程规定了除颤分析仪的计量特性、通用技术要求、校准条件、校准项目、校准方法、校准结果、校准证书和校准周期等要求。本规程适用于新配置、使用中和维修后的除颤分析仪的校准
Calibration regulation for defibrillator analyzers