服务热线:400-635-0567

溶解性总固体检测

发布时间:2024-05-27 17:49:26 - 更新时间:2024年06月29日 15:22

点击量:0

军工检测 其他检测

GB/T 27841-2011 工业用化学品.具有高溶解性的固体和液体水溶性测定 烧瓶法

本标准规定了利用烧瓶法测定工业用化学品(以下简称产品)水溶性的方法。 本标准适用于水中稳定性良好且溶解性较高(大于10g/L)的基本纯净物质。 本标准不适用于不纯的产品(例如某些表面活性剂)、不稳定的产品和在水中不稳定的产品,测试物中杂质的存在将很大程度上影响该物质的水溶性测定结果;不适用于水中稳定性良好但溶解性较低(小于10g/L)的基本纯净物质。

Chemical products for industrial use.Determination of hydrosolubility of solids and liquids with high solubility.Flask method

GB/T 22227-2008 工业用化学品.具有低溶解性的固体和液体水溶性测定.圆柱层析法

本标准规定了利用圆柱层析测定工业用化学品水溶解性的方法。 本标准不可用于不纯的产品(如某些表面的银)、不稳定的产品和在水中不稳定的产品。 测试物中杂质的存在将在很大程度上影响该物质的水溶性测定结果。

Chemical products for industrial use.Determination of water solubility of solid and liquids with low solubility.Column elution method

T/QAS 030-2021 卤水 溶解性总固体的测定 重量法

本文件规定了卤水溶解性总固体的测定方法。 本文件适用于卤水溶解性总固体的测定,测定范围: 2.0 g/L~500 g/L。

ASTM D5232-2013 测定固体, 半固体或者液体废料稳定性和溶解性的标准试验方法

5.1x00a0;This test method will identify waste materials that are potentially unstable when they come in contact with other materials at a waste treatment or disposal site. 5.2x00a0;This test method will serve to determine the miscibility of waste materials with various media, including other wastes. 5.3x00a0;This test method may not be applicable to all wastes. The appropriateness of these tests depends upon the proposed management of the waste. 5.4x00a0;Since the initiation of some chemical reactions are slow to take place, the user may wish to establish reagent-to-waste contact times prior to observing the mixes for any reactions. 1.1x00a0;This test method is designed to determine whether a waste material reacts when it is mixed with air, water, strong acid, strong base, an oil/solvent mixture, other waste mixtures, or solid media such as a geological formation or solidification agents. 1.2x00a0;The miscibility of the waste material with the above media can also be defined. Note 1x2014;The following ASTM standards provide supplemental information: Test Methods D4978, D4979, D4980, D4981, D4982, D5049, D5057, and D5058. 1.3x00a0;The values stated in SI units are to be regarded as standard. No other units of measurement are included in this standard. 1.4x00a0;This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use. For specific hazard statements, see Section 8.

Standard Test Method for Determining the Stability and Miscibility of a Solid, Semi-Solid, or Liquid Waste Material

ASTM D5907-2010 水中可过滤物(总溶解性固体)和不可过滤物(总悬浮固体)的标准试验方法

Solids, both as filterable matter (TDS) and nonfilterable matter (TSS), are important in the treating of raw water and wastewater, and in monitoring of streams. Waste solids impose a suspended and settleable residue in receiving waters. Suspended and soluble materials provide a matrix for some biological slime and, in sufficient quantity, impair respiration of organisms. These solids may create nuisance slime beds and odors while imposing a long-term biological oxidation load over limited receiving water areas. Knowledge of suspended and soluble materials is important in treating raw water supplies. Knowledge of solids loading can aid in determining the type or amount of treatment, or both, necessary to make the water acceptable for use. Such information may also be used to determine acceptability of water after treatment. Too little treatment may not be desirable and excess treatment costs money. Stream monitoring is important for environmental reasons, such as compliance with discharge permits. Stream improvements, water pollution monitoring, mass wasting, algal studies, and sediment loads are but a few of the many reasons streams are monitored.1.1 These test methods cover the determination of filterable matter, total dissolved solids (TDS), and nonfilterable matter, total suspended solids (TSS), in drinking, surface, and saline waters, domestic and industrial wastes. The practical range of the determination of nonfilterable particulate matter (TSS) is 4 to 20 000 mg/L. The practical range of the determination of filterable matter (TDS) is 10 mg/L to 150 000 x00B5;g/g. 1.2 Since the results measured by this test are operationally defined, careful attention must be paid to following the procedure as specified. 1.3 The test methods appear in the following order: Filterable Matter (TDS) and Nonfilterable Matter (TSS), mg/LSections 10-14 Total Dissolved Solids High Precision Method, x00B5;g/gSections 15-19 1.4 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use. For a specific hazard statement, see Section 8.

Standard Test Methods for Filterable Matter (Total Dissolved Solids) and Nonfilterable Matter (Total Suspended Solids) in Water

SANS 5213-2005 水.溶解性固体含量

Specifies a method of measuring the concentration of dissolved solids in water and in wastewater by gravimetric determination of the dry residue of the sample after filtration through a glass fibre filter of nominal pore size 1,0 鎚 ?0,2 鎚.

Water - Dissolved solids content

CJ/T 3018.4-1993 生活垃圾渗沥水.总溶解性固体与总悬浮性固体的测定

Leachate.Determination of total dissolved solids and total suspended solids

DZ/T 0064.9-1993 地下水质检验方法.溶解性固体总量的测定

本标准规定了105℃烘干测定溶解性固体总量的方法。 本标准适用于不含永久硬度的地下水中溶解性固体总量的测定。

DZ/T 0064.9-2021 地下水质分析方法 第9部分:溶解性固体总量的测定 重量法

上一篇: 腈苯唑检测
检测流程
填写并提交定制服务需求表
技术评估和方案讨论
对选定的试验方法进行报价
合同签定与付款
按期交付检测报告和相关数据
想了解更多检测项目
请点击咨询在线工程师
点击咨询
联系我们
服务热线:400-635-0567
地址:北京市丰台区航丰路8号院1号楼1层121
邮编:10000
总机:400-635-0567
联系我们

服务热线:400-635-0567

投诉建议:010-82491398

报告问题解答:010-8646-0567-8

周期、价格等

咨询

技术咨询